HIGH · 9.3

CVE-2013-5021

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlie...

Vulnerability Description

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.

CVSS Score

9.3

HIGH

AV:N/AC:M/Au:N/C:C/I:C/A:C
Confidentiality
COMPLETE
Integrity
COMPLETE
Availability
COMPLETE

Affected Products

VendorProductVersions
NiLabview<= 2012
NiLabwindows<= 2012
NiMeasurementstudio<= 2013
NiTeststand<= 2012
AbbDatamanager1.0.0

Related Weaknesses (CWE)

References

FAQ

What is CVE-2013-5021?

CVE-2013-5021 is a vulnerability with a CVSS score of 9.3 (HIGH). Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlie...

How severe is CVE-2013-5021?

CVE-2013-5021 has been rated HIGH with a CVSS base score of 9.3/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2013-5021?

Check the references section above for vendor advisories and patch information. Affected products include: Ni Labview, Ni Labwindows, Ni Measurementstudio, Ni Teststand, Abb Datamanager.