Vulnerability Description
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVSS Score
HIGH
Affected Products
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Dnp3 Tcp Firmware | - |
| Siemens | Iec 61850 Firmware | < 4.33 |
| Siemens | Iec104 Firmware | - |
| Siemens | Modbus Tcp Firmware | - |
| Siemens | Profinet Io Firmware | - |
| Siemens | En100 | - |
| Siemens | Cp100 Firmware | < 7.80 |
| Siemens | Cp200 Firmware | - |
| Siemens | Cp300 Firmware | < 7.80 |
| Siemens | 6Md85 | - |
| Siemens | 6Md86 | - |
| Siemens | 7Ke85 | - |
| Siemens | 7Sa82 | - |
| Siemens | 7Sa86 | - |
| Siemens | 7Sa87 | - |
| Siemens | 7Sd82 | - |
| Siemens | 7Sd86 | - |
| Siemens | 7Sd87 | - |
| Siemens | 7Sj82 | - |
| Siemens | 7Sj85 | - |
Related Weaknesses (CWE)
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdfMitigationPatchVendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdfMitigationPatchVendor Advisory
- https://www.securityfocus.com/bid/106221
- https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdfMitigationPatchVendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdfMitigationPatchVendor Advisory
- https://www.securityfocus.com/bid/106221
FAQ
What is CVE-2018-11452?
CVE-2018-11452 is a vulnerability with a CVSS score of 7.5 (HIGH). A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware vari...
How severe is CVE-2018-11452?
CVE-2018-11452 has been rated HIGH with a CVSS base score of 7.5/10. Review the CVSS metrics above for detailed severity breakdown.
Is there a patch for CVE-2018-11452?
Check the references section above for vendor advisories and patch information. Affected products include: Siemens Dnp3 Tcp Firmware, Siemens Iec 61850 Firmware, Siemens Iec104 Firmware, Siemens Modbus Tcp Firmware, Siemens Profinet Io Firmware.