HIGH · 7.8

CVE-2018-11460

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions <...

Vulnerability Description

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

CVSS Score

7.8

HIGH

CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH

Affected Products

VendorProductVersions
SiemensSinumerik 808D V4.7 FirmwareAll versions
SiemensSinumerik 808D V4.7-
SiemensSinumerik 808D V4.8 FirmwareAll versions
SiemensSinumerik 808D V4.8-
SiemensSinumerik 828D V4.7 Firmware<= 4.7
SiemensSinumerik 828D V4.7-
SiemensSinumerik 840D Sl V4.7 Firmware<= 4.7
SiemensSinumerik 840D Sl V4.7All versions
SiemensSinumerik 840D Sl V4.8 Firmware<= 4.8
SiemensSinumerik 840D Sl V4.8-

Related Weaknesses (CWE)

References

FAQ

What is CVE-2018-11460?

CVE-2018-11460 is a vulnerability with a CVSS score of 7.8 (HIGH). A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions <...

How severe is CVE-2018-11460?

CVE-2018-11460 has been rated HIGH with a CVSS base score of 7.8/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2018-11460?

Check the references section above for vendor advisories and patch information. Affected products include: Siemens Sinumerik 808D V4.7 Firmware, Siemens Sinumerik 808D V4.7, Siemens Sinumerik 808D V4.8 Firmware, Siemens Sinumerik 808D V4.8, Siemens Sinumerik 828D V4.7 Firmware.