MEDIUM · 5.9

CVE-2018-16563

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware varia...

Vulnerability Description

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

CVSS Score

5.9

MEDIUM

CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
NETWORK
Attack Complexity
HIGH
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
NONE
Integrity
NONE
Availability
HIGH

Affected Products

VendorProductVersions
SiemensSiprotec 5 With Cpu Variant Cp100< 7.82
SiemensSiprotec 5 With Cpu Variant Cp200< 7.58
SiemensSiprotec 5 With Cpu Variant Cp300< 7.82
Siemens6Md85-
Siemens6Md86-
Siemens7Ke85-
Siemens7Sa82-
Siemens7Sa86-
Siemens7Sa87-
Siemens7Sd82-
Siemens7Sd86-
Siemens7Sd87-
Siemens7Sj82-
Siemens7Sj85-
Siemens7Sj86-
Siemens7Sk82-
Siemens7Sk85-
Siemens7Sl82-
Siemens7Sl86-
Siemens7Sl87-

References

FAQ

What is CVE-2018-16563?

CVE-2018-16563 is a vulnerability with a CVSS score of 5.9 (MEDIUM). A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware varia...

How severe is CVE-2018-16563?

CVE-2018-16563 has been rated MEDIUM with a CVSS base score of 5.9/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2018-16563?

Check the references section above for vendor advisories and patch information. Affected products include: Siemens Siprotec 5 With Cpu Variant Cp100, Siemens Siprotec 5 With Cpu Variant Cp200, Siemens Siprotec 5 With Cpu Variant Cp300, Siemens 6Md85, Siemens 6Md86.