HIGH · 8.8

CVE-2018-4845

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 S...

Vulnerability Description

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.

CVSS Score

8.8

HIGH

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH

Affected Products

VendorProductVersions
SiemensRapidpoint 400 Firmware-
SiemensRapidpoint 400-
SiemensRapidpoint 500 Firmware<= 2.3
SiemensRapidpoint 500-
SiemensRapidlab 1200 Firmware< 3.3
SiemensRapidlab 1200-

Related Weaknesses (CWE)

References

FAQ

What is CVE-2018-4845?

CVE-2018-4845 is a vulnerability with a CVSS score of 8.8 (HIGH). A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 S...

How severe is CVE-2018-4845?

CVE-2018-4845 has been rated HIGH with a CVSS base score of 8.8/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2018-4845?

Check the references section above for vendor advisories and patch information. Affected products include: Siemens Rapidpoint 400 Firmware, Siemens Rapidpoint 400, Siemens Rapidpoint 500 Firmware, Siemens Rapidpoint 500, Siemens Rapidlab 1200 Firmware.