HIGH · 7.5

CVE-2021-25662

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (inc...

Vulnerability Description

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.

CVSS Score

7.5

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
NONE
Integrity
NONE
Availability
HIGH

Affected Products

VendorProductVersions
SiemensSimatic Wincc Runtime Advanced< 16
SiemensSimatic Hmi Comfort Outdoor Panels 7\" Firmware< 16
SiemensSimatic Hmi Comfort Outdoor Panels 7\"-
SiemensSimatic Hmi Comfort Outdoor Panels 15\" Firmware< 16
SiemensSimatic Hmi Comfort Outdoor Panels 15\"-
SiemensSimatic Hmi Comfort Panels 4\" Firmware< 16
SiemensSimatic Hmi Comfort Panels 4\"-
SiemensSimatic Hmi Comfort Panels 22\" Firmware< 16
SiemensSimatic Hmi Comfort Panels 22\"-
SiemensSimatic Hmi Ktp Mobile Panels Ktp400F Firmware< 16
SiemensSimatic Hmi Ktp Mobile Panels Ktp400F-
SiemensSimatic Hmi Ktp Mobile Panels Ktp700 Firmware< 16
SiemensSimatic Hmi Ktp Mobile Panels Ktp700-
SiemensSimatic Hmi Ktp Mobile Panels Ktp700F Firmware< 16
SiemensSimatic Hmi Ktp Mobile Panels Ktp700F-
SiemensSimatic Hmi Ktp Mobile Panels Ktp900 Firmware< 16
SiemensSimatic Hmi Ktp Mobile Panels Ktp900-
SiemensSimatic Hmi Ktp Mobile Panels Ktp900F Firmware< 16
SiemensSimatic Hmi Ktp Mobile Panels Ktp900F-

Related Weaknesses (CWE)

References

FAQ

What is CVE-2021-25662?

CVE-2021-25662 is a vulnerability with a CVSS score of 7.5 (HIGH). A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (inc...

How severe is CVE-2021-25662?

CVE-2021-25662 has been rated HIGH with a CVSS base score of 7.5/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2021-25662?

Check the references section above for vendor advisories and patch information. Affected products include: Siemens Simatic Wincc Runtime Advanced, Siemens Simatic Hmi Comfort Outdoor Panels 7\" Firmware, Siemens Simatic Hmi Comfort Outdoor Panels 7\", Siemens Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Siemens Simatic Hmi Comfort Outdoor Panels 15\".