HIGH · 7.5

CVE-2021-27383

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (inc...

Vulnerability Description

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.

CVSS Score

7.5

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
NONE
Integrity
NONE
Availability
HIGH

Affected Products

VendorProductVersions
SiemensSimatic Wincc Runtime Advanced< 16
SiemensSinamics Sh150 FirmwareAll versions
SiemensSinamics Sh150-
SiemensSinamics Sm150I FirmwareAll versions
SiemensSinamics Sm150I-
SiemensSinamics Gh150 FirmwareAll versions
SiemensSinamics Gh150-
SiemensSinamics Gl150 FirmwareAll versions
SiemensSinamics Gl150-
SiemensSinamics Gm150 FirmwareAll versions
SiemensSinamics Gm150-
SiemensSinamics Sl150 FirmwareAll versions
SiemensSinamics Sl150-
SiemensSinamics Sm120 FirmwareAll versions
SiemensSinamics Sm120-
SiemensSinamics Sm150 FirmwareAll versions
SiemensSinamics Sm150-
SiemensSimatic Hmi Comfort Outdoor Panels 7\" Firmware< 16
SiemensSimatic Hmi Comfort Outdoor Panels 7\"-
SiemensSimatic Hmi Comfort Outdoor Panels 15\" Firmware< 16

Related Weaknesses (CWE)

References

FAQ

What is CVE-2021-27383?

CVE-2021-27383 is a vulnerability with a CVSS score of 7.5 (HIGH). A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (inc...

How severe is CVE-2021-27383?

CVE-2021-27383 has been rated HIGH with a CVSS base score of 7.5/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2021-27383?

Check the references section above for vendor advisories and patch information. Affected products include: Siemens Simatic Wincc Runtime Advanced, Siemens Sinamics Sh150 Firmware, Siemens Sinamics Sh150, Siemens Sinamics Sm150I Firmware, Siemens Sinamics Sm150I.