CRITICAL · 9.8

CVE-2021-27410

The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: ver...

Vulnerability Description

The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).

CVSS Score

9.8

CRITICAL

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH

Affected Products

VendorProductVersions
HillromConnex Central Station< 1.8.6
HillromConnex Device Integration Suite Network Connectivity Engine< 5.3
HillromConnex Integrated Wall System< 2.43.02
HillromConnex Spot Monitor< 1.52
HillromConnex Vital Signs Monitor< 2.43.02
HillromService Monitor< 1.7.0.0
HillromService Tool< 1.10
HillromSoftware Development Kit< 3.2
HillromSpot Vital Signs 4400< 1.11.00

Related Weaknesses (CWE)

References

FAQ

What is CVE-2021-27410?

CVE-2021-27410 is a vulnerability with a CVSS score of 9.8 (CRITICAL). The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: ver...

How severe is CVE-2021-27410?

CVE-2021-27410 has been rated CRITICAL with a CVSS base score of 9.8/10. This is considered a critical vulnerability requiring immediate attention.

Is there a patch for CVE-2021-27410?

Check the references section above for vendor advisories and patch information. Affected products include: Hillrom Connex Central Station, Hillrom Connex Device Integration Suite Network Connectivity Engine, Hillrom Connex Integrated Wall System, Hillrom Connex Spot Monitor, Hillrom Connex Vital Signs Monitor.