HIGH · 7.5

CVE-2021-31885

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet)...

Vulnerability Description

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)

CVSS Score

7.5

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
NONE
Availability
NONE

Affected Products

VendorProductVersions
SiemensCapital VstarAll versions
SiemensNucleus NetAll versions
SiemensNucleus Readystart V3< 2017.02.4
SiemensNucleus Readystart V4< 4.1.1
SiemensNucleus Source CodeAll versions
SiemensApogee Modular Building Controller FirmwareAll versions
SiemensApogee Modular Building Controller-
SiemensApogee Modular Equiment Controller FirmwareAll versions
SiemensApogee Modular Equiment Controller-
SiemensApogee Pxc Compact FirmwareAll versions
SiemensApogee Pxc Compact-
SiemensApogee Pxc Modular FirmwareAll versions
SiemensApogee Pxc Modular-
SiemensTalon Tc Compact FirmwareAll versions
SiemensTalon Tc Compact-
SiemensTalon Tc Modular FirmwareAll versions
SiemensTalon Tc Modular-

Related Weaknesses (CWE)

References

FAQ

What is CVE-2021-31885?

CVE-2021-31885 is a vulnerability with a CVSS score of 7.5 (HIGH). A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet)...

How severe is CVE-2021-31885?

CVE-2021-31885 has been rated HIGH with a CVSS base score of 7.5/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2021-31885?

Check the references section above for vendor advisories and patch information. Affected products include: Siemens Capital Vstar, Siemens Nucleus Net, Siemens Nucleus Readystart V3, Siemens Nucleus Readystart V4, Siemens Nucleus Source Code.