Vulnerability Description
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVSS Score
CRITICAL
Affected Products
| Vendor | Product | Versions |
|---|---|---|
| Schneider-Electric | Smt Series 1015 Ups Firmware | <= 04.5 |
| Schneider-Electric | Smt Series 1015 Ups | - |
| Schneider-Electric | Smc Series 1018 Ups Firmware | <= 04.2 |
| Schneider-Electric | Smc Series 1018 Ups | - |
| Schneider-Electric | Smtl Series 1026 Ups Firmware | <= 02.9 |
| Schneider-Electric | Smtl Series 1026 Ups | - |
| Schneider-Electric | Scl Series 1029 Ups Firmware | <= 02.5 |
| Schneider-Electric | Scl Series 1029 Ups | - |
| Schneider-Electric | Scl Series 1030 Ups Firmware | <= 02.5 |
| Schneider-Electric | Scl Series 1030 Ups | - |
| Schneider-Electric | Scl Series 1036 Ups Firmware | <= 02.5 |
| Schneider-Electric | Scl Series 1036 Ups | - |
| Schneider-Electric | Scl Series 1037 Ups Firmware | <= 03.1 |
| Schneider-Electric | Scl Series 1037 Ups | - |
| Schneider-Electric | Smx Series 1031 Ups Firmware | <= 03.1 |
| Schneider-Electric | Smx Series 1031 Ups | - |
| Schneider-Electric | Smt Series 18 Ups Firmware | <= 09.8 |
| Schneider-Electric | Smt Series 18 Ups | - |
| Schneider-Electric | Smt Series 1040 Ups Firmware | <= 01.2 |
| Schneider-Electric | Smt Series 1040 Ups | - |
Related Weaknesses (CWE)
References
- https://www.se.com/ww/en/download/document/SEVD-2022-067-02/Vendor Advisory
- https://www.se.com/ww/en/download/document/SEVD-2022-067-02/Vendor Advisory
FAQ
What is CVE-2022-0715?
CVE-2022-0715 is a vulnerability with a CVSS score of 9.1 (CRITICAL). A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected ...
How severe is CVE-2022-0715?
CVE-2022-0715 has been rated CRITICAL with a CVSS base score of 9.1/10. This is considered a critical vulnerability requiring immediate attention.
Is there a patch for CVE-2022-0715?
Check the references section above for vendor advisories and patch information. Affected products include: Schneider-Electric Smt Series 1015 Ups Firmware, Schneider-Electric Smt Series 1015 Ups, Schneider-Electric Smc Series 1018 Ups Firmware, Schneider-Electric Smc Series 1018 Ups, Schneider-Electric Smtl Series 1026 Ups Firmware.