Vulnerability Description
The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller (IC) protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller (IC) protocol (57612/UDP). The potential impact is: Compromise of credentials. Several Trend Controls building automation controllers utilize the Inter-Controller (IC) protocol in for information exchange and automation purposes. This protocol offers authentication in the form of a 4-digit PIN in order to protect access to sensitive operations like strategy uploads and downloads as well as optional 0-30 character username and password protection for web page access protection. Both the PIN and usernames and passwords are transmitted in cleartext, allowing an attacker with passive interception capabilities to obtain these credentials. Credentials are transmitted in cleartext. An attacker who obtains Trend IC credentials can carry out sensitive engineering actions such as manipulating controller strategy or configuration settings. If the credentials in question are (re)used for other applications, their compromise could potentially facilitate lateral movement.
CVSS Score
MEDIUM
Affected Products
| Vendor | Product | Versions |
|---|---|---|
| Honeywell | Trend Iq412 Firmware | All versions |
| Honeywell | Trend Iq412 | - |
| Honeywell | Trend Iq411 Firmware | All versions |
| Honeywell | Trend Iq411 | - |
| Honeywell | Trend Iq422 Firmware | All versions |
| Honeywell | Trend Iq422 | - |
| Honeywell | Trend Iq4Nc Firmware | All versions |
| Honeywell | Trend Iq4Nc | - |
| Honeywell | Trend Iq4E Firmware | All versions |
| Honeywell | Trend Iq4E | - |
Related Weaknesses (CWE)
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-08Third Party AdvisoryUS Government Resource
- https://www.forescout.com/blog/Third Party Advisory
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-242-08Third Party AdvisoryUS Government Resource
- https://www.forescout.com/blog/Third Party Advisory
FAQ
What is CVE-2022-30312?
CVE-2022-30312 is a vulnerability with a CVSS score of 6.5 (MEDIUM). The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller (IC) protocol cleartex...
How severe is CVE-2022-30312?
CVE-2022-30312 has been rated MEDIUM with a CVSS base score of 6.5/10. Review the CVSS metrics above for detailed severity breakdown.
Is there a patch for CVE-2022-30312?
Check the references section above for vendor advisories and patch information. Affected products include: Honeywell Trend Iq412 Firmware, Honeywell Trend Iq412, Honeywell Trend Iq411 Firmware, Honeywell Trend Iq411, Honeywell Trend Iq422 Firmware.