HIGH · 7.1

CVE-2023-27975

CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of ...

Vulnerability Description

CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.

CVSS Score

7.1

HIGH

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
NONE

Affected Products

VendorProductVersions
Schneider-ElectricEcostruxure Control Expert< 16.0
Schneider-ElectricEcostruxure Process Expert< 2023

Related Weaknesses (CWE)

References

FAQ

What is CVE-2023-27975?

CVE-2023-27975 is a vulnerability with a CVSS score of 7.1 (HIGH). CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of ...

How severe is CVE-2023-27975?

CVE-2023-27975 has been rated HIGH with a CVSS base score of 7.1/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2023-27975?

Check the references section above for vendor advisories and patch information. Affected products include: Schneider-Electric Ecostruxure Control Expert, Schneider-Electric Ecostruxure Process Expert.