CRITICAL · 9.1

CVE-2023-36751

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX15...

Vulnerability Description

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The install-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

CVSS Score

9.1

CRITICAL

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
HIGH
User Interaction
NONE
Scope
CHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH

Affected Products

VendorProductVersions
SiemensRuggedcom Rox Mx5000 Firmware< 2.16.0
SiemensRuggedcom Rox Mx5000-
SiemensRuggedcom Rox Mx5000Re Firmware< 2.16.0
SiemensRuggedcom Rox Mx5000Re-
SiemensRuggedcom Rox Rx1400 Firmware< 2.16.0
SiemensRuggedcom Rox Rx1400-
SiemensRuggedcom Rox Rx1500 Firmware< 2.16.0
SiemensRuggedcom Rox Rx1500-
SiemensRuggedcom Rox Rx1501 Firmware< 2.16.0
SiemensRuggedcom Rox Rx1501-
SiemensRuggedcom Rox Rx1510 Firmware< 2.16.0
SiemensRuggedcom Rox Rx1510-
SiemensRuggedcom Rox Rx1511 Firmware< 2.16.0
SiemensRuggedcom Rox Rx1511-
SiemensRuggedcom Rox Rx1512 Firmware< 2.16.0
SiemensRuggedcom Rox Rx1512-
SiemensRuggedcom Rox Rx1524 Firmware< 2.16.0
SiemensRuggedcom Rox Rx1524-
SiemensRuggedcom Rox Rx1536 Firmware< 2.16.0
SiemensRuggedcom Rox Rx1536-

Related Weaknesses (CWE)

References

FAQ

What is CVE-2023-36751?

CVE-2023-36751 is a vulnerability with a CVSS score of 9.1 (CRITICAL). A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX15...

How severe is CVE-2023-36751?

CVE-2023-36751 has been rated CRITICAL with a CVSS base score of 9.1/10. This is considered a critical vulnerability requiring immediate attention.

Is there a patch for CVE-2023-36751?

Check the references section above for vendor advisories and patch information. Affected products include: Siemens Ruggedcom Rox Mx5000 Firmware, Siemens Ruggedcom Rox Mx5000, Siemens Ruggedcom Rox Mx5000Re Firmware, Siemens Ruggedcom Rox Mx5000Re, Siemens Ruggedcom Rox Rx1400 Firmware.