HIGH · 8.2

CVE-2023-5986

A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers ca...

Vulnerability Description

A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed.

CVSS Score

8.2

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
CHANGED
Confidentiality
HIGH
Integrity
LOW
Availability
NONE

Affected Products

VendorProductVersions
Schneider-ElectricEcostruxure Power Monitoring Expert2020

Related Weaknesses (CWE)

References

FAQ

What is CVE-2023-5986?

CVE-2023-5986 is a vulnerability with a CVSS score of 8.2 (HIGH). A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers ca...

How severe is CVE-2023-5986?

CVE-2023-5986 has been rated HIGH with a CVSS base score of 8.2/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2023-5986?