HIGH · 8.1

CVE-2024-31854

A vulnerability has been identified in SICAM TOOLBOX II (All versions < V07.11). During establishment of a https connection to the TLS server of a managed device, the affected application doesn't chec...

Vulnerability Description

A vulnerability has been identified in SICAM TOOLBOX II (All versions < V07.11). During establishment of a https connection to the TLS server of a managed device, the affected application doesn't check device's certificate common name against an expected value. This could allow an attacker to execute an on-path network (MitM) attack.

CVSS Score

8.1

HIGH

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
NETWORK
Attack Complexity
HIGH
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH

Affected Products

VendorProductVersions
SiemensSicam Toolbox Ii< 07.11

Related Weaknesses (CWE)

References

FAQ

What is CVE-2024-31854?

CVE-2024-31854 is a vulnerability with a CVSS score of 8.1 (HIGH). A vulnerability has been identified in SICAM TOOLBOX II (All versions < V07.11). During establishment of a https connection to the TLS server of a managed device, the affected application doesn't chec...

How severe is CVE-2024-31854?

CVE-2024-31854 has been rated HIGH with a CVSS base score of 8.1/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2024-31854?

Check the references section above for vendor advisories and patch information. Affected products include: Siemens Sicam Toolbox Ii.