Vulnerability Description
The hard drives of the device are not encrypted using a full volume encryption feature such as BitLocker. This allows an attacker with physical access to the device to use an alternative operating system to interact with the hard drives, completely circumventing the Windows login. The attacker can read from and write to all files on the hard drives.
CVSS Score
HIGH
Affected Products
| Vendor | Product | Versions |
|---|---|---|
| Endress | Meac300-Fnade4 Firmware | All versions |
| Endress | Meac300-Fnade4 | - |
Related Weaknesses (CWE)
References
- https://sick.com/psirtVendor Advisory
- https://sick.com/psirtVendor Advisory
- https://www.cisa.gov/resources-tools/resources/ics-recommended-practicesUS Government Resource
- https://www.endress.comProduct
- https://www.first.org/cvss/calculator/3.1Not Applicable
- https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0008.jsonVendor Advisory
- https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0008.pdfVendor Advisory
FAQ
What is CVE-2025-27460?
CVE-2025-27460 is a vulnerability with a CVSS score of 7.6 (HIGH). The hard drives of the device are not encrypted using a full volume encryption feature such as BitLocker. This allows an attacker with physical access to the device to use an alternative operating sys...
How severe is CVE-2025-27460?
CVE-2025-27460 has been rated HIGH with a CVSS base score of 7.6/10. Review the CVSS metrics above for detailed severity breakdown.
Is there a patch for CVE-2025-27460?
Check the references section above for vendor advisories and patch information. Affected products include: Endress Meac300-Fnade4 Firmware, Endress Meac300-Fnade4.