MEDIUM · 6.3

CVE-2026-2491

Socomec DIRIS A-40 HTTP API Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Socomec DIRIS A-40 power mon...

Vulnerability Description

Socomec DIRIS A-40 HTTP API Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Socomec DIRIS A-40 power monitoring devices. Authentication is not required to exploit this vulnerability. The specific flaw exists within the web API implementation, which listens on TCP port 80 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-23993.

CVSS Score

6.3

MEDIUM

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Attack Vector
ADJACENT_NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality
LOW
Integrity
LOW
Availability
LOW

Related Weaknesses (CWE)

References

FAQ

What is CVE-2026-2491?

CVE-2026-2491 is a vulnerability with a CVSS score of 6.3 (MEDIUM). Socomec DIRIS A-40 HTTP API Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Socomec DIRIS A-40 power mon...

How severe is CVE-2026-2491?

CVE-2026-2491 has been rated MEDIUM with a CVSS base score of 6.3/10. Review the CVSS metrics above for detailed severity breakdown.

Is there a patch for CVE-2026-2491?

Check the references section above for vendor advisories and patch information. Review vendor security bulletins for remediation guidance.