Vulnerability Description
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.
CVSS Score
MEDIUM
Related Weaknesses (CWE)
References
FAQ
What is CVE-2026-25599?
CVE-2026-25599 is a vulnerability with a CVSS score of 6.3 (MEDIUM). Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enab...
How severe is CVE-2026-25599?
CVE-2026-25599 has been rated MEDIUM with a CVSS base score of 6.3/10. Review the CVSS metrics above for detailed severity breakdown.
Is there a patch for CVE-2026-25599?
Check the references section above for vendor advisories and patch information. Review vendor security bulletins for remediation guidance.