Vulnerability Description
There is an insecure default credentials vulnerability in NI grpc-device when TLS configuration is not present and the server is bound beyond loopback. This may allow an unauthenticated user access to the server on the local network. This affects NI grpc-device 2.17.0 and prior versions.
CVSS Score
CRITICAL
Affected Products
| Vendor | Product | Versions |
|---|---|---|
| Ni | Instrumentstudio | <= 2025 |
| Ni | Ni Grpc Device Server | < 2.18.0 |
Related Weaknesses (CWE)
References
- https://github.com/ni/grpc-device/security/advisories/GHSA-fhhw-37q8-6562Vendor Advisory
- https://www.ni.com/en/support/security/available-critical-and-security-updates-fVendor Advisory
FAQ
What is CVE-2026-9142?
CVE-2026-9142 is a vulnerability with a CVSS score of 9.1 (CRITICAL). There is an insecure default credentials vulnerability in NI grpc-device when TLS configuration is not present and the server is bound beyond loopback. This may allow an unauthenticated user access t...
How severe is CVE-2026-9142?
CVE-2026-9142 has been rated CRITICAL with a CVSS base score of 9.1/10. This is considered a critical vulnerability requiring immediate attention.
Is there a patch for CVE-2026-9142?
Check the references section above for vendor advisories and patch information. Affected products include: Ni Instrumentstudio, Ni Ni Grpc Device Server.